Awarded as Top 10 Crane Manufacturer 2021 By Industry Outlook

Flame Proof Cranes and Hoists

Flammable gases, vapours, mists, and dusts form an explosive atmosphere with the oxygen in the air if present or leaked during the manufacturing process. If this atmosphere is ignited, explosions take place, which can result in severe harm to human life and property. Since Electric Hoist or Cranes houses electrical Switchgears, Motors etc which can produce sparks and these little sparks can provide sufficient ignition in above atmosphere to form explosions,  Reva provides EX electric cranes, explosion proof electric cranes suitable for Zone 1 & 2 (gas) and Zone 21 & 22 (dust) or suitable for both areas i.e combination of Zone 1 & 2 (gas) and Zone 21 & 22 (dust).

EX cranes and winches are also known as anti sparking cranes, spark proof cranes or explosion proof cranes. Although there are many standards which are followed worldwide to define the above zones, all of them reach to the similar conclusions. ISO, BS, NEMA are some of the names. Indian standard IS:2148 was also available earlier but is now withdrawn and international standards are being followed instead.

Zone classification

Gases
Zone 0 – A place in which an explosive atmosphere consisting of a mixture with air of dangerous substances in the form of gas, vapor or mist is present continuously or for long periods or frequently.

Zone 1 – A place in which an explosive atmosphere consisting of a mixture with air of dangerous substances in the form of gas, vapor or mist is likely to occur in normal operation occasionally.

Zone 2 – A place in which an explosive atmosphere consisting of a mixture with air of dangerous substances in the form of gas, vapor or mist is not likely to occur in normal operation but, if it does occur, will persist for a short period only.

Dust
Zone 20 – A place in which an explosive atmosphere in the form of a cloud of combustible dust in air is present continuously, or for long periods or frequently.

Zone 21 – A place in which an explosive atmosphere in the form of a cloud of combustible dust in air is likely to occur in normal operation occasionally.

Zone 22 – A place in which an explosive atmosphere in the form or a cloud of combustible dust in air is not likely to occur in normal operation but, if it does occur, will persist for a short period only.

Atex directive http://eur-lex.europa.eu/legal-content/EN/TXT/PDF/?uri=CELEX:32014L0034&from=EN

Atex guidelines
http://ec.europa.eu/DocsRoom/documents/16402/attachments/1/translations/en/renditions/native

Benefits of Choosing Reva Flame Proof Cranes And Hoists
  • Use Reva proven Hoists and cranes.
  • Use of Panels, Motors, Limit switches which are ATEX certified.
  • Our engineers have detailed knowledge of the ATEX directive.
  • Already supplied for stringent applications wherein both dust and gases are present.
Product Catalogue

Download catalogue to know more about Flame Proof Cranes And Hoists

Download
Download Enquiry Form

Testimonials

Performance is satisfactory.

Two nos capacity 1.5 Ton Jib Cranes Mtrs having span of 5.0 Mtrs. and Lift of 7.0 Mtrs. has been in operation and performance is satisfactory.

GRAND PRIX ENGINEERING (P) LTD
Faridabad
Satisfactorily.

The EOT Crane having 5 Ton SWL Capacity has been Installed and Commissioned by Reva Industries Ltd. The work has been carried out Satisfactorily.

STORE OFFICER
Cat Indore
SGL GARBON INDIA PVT LTD

The crane has been in operation since 27 FEB, 2012 and performance of the crane has been satisfactory

SGL GARBON INDIA PVT LTD
Faridabad
Satisfactorily.

The Crane was load tested and handed over for erection of CW pumps on 16th January 2012. The crane has been in operation and performance is satisfactory.

FLOWMORE LIMITED
Faridabad
RELAINCE INFRASTRUCTURE LIMITED

The crane has been in operation and performance of the crane has been satisfactory.

RELAINCE INFRASTRUCTURE LIMITED
Faridabad
satisfactory.

The crane has been in operation since one year and 3 months performance of the crane has been found satisfactory.

BRIJESH KUMAR MISHRA
Power Projects, Kirloskar Brothers Limited
satisfactory.

The crane has been in operation since 10 Jan, 2011 and performance of the crane has been satisfactory.

MR. SUBHASH KHENDALWAL
U.S.K Exports Managing Director
satisfactory.

The crane has been in operation since 18th Feb, 2011 and performance of the crane has been found to be satisfactory.

MR. V.V. NAMJOSHI
M/S MAITHON POWER LIMITED Head Construction
ABIR INFRASTRUCTURE PVT. LTD.

The crane has been in operation since 14th April, 2014 and performance of the crane has been satisfactory.

ABIR INFRASTRUCTURE PVT. LTD.
Faridabad
Satisfactory.

The Crane was load tested and handed over for plant operation on 9th october 2011. The crane has been in operation and performation is Satisfactory.

VINEET ARORA
Flowmore Limited Sr. Manages - Projects
satisfactory.

The crane has been in operation since OCT, 2008 and performance of the crane has been satisfactory.

EVEREST POWER PVT. LTD.
Faridabad
Download catalogue to know more about our Products, Just download the pdf
Call Our Experts